Question Detail
How to investigate the low yield of high copy plasmid small extraction kit
Reagent Selection
💡
How to Answer This Question
-
1
Read the Context
Read the full description, category and tags to understand the real scenario.
-
2
Give an Actionable Answer
Give concrete steps, cautions and reasoning — not just a conclusion.
-
3
Cite Sources
Reference standards, papers or product manuals to make the answer more credible.
-
4
Wait for Acceptance
You will be notified if accepted. Continue the discussion in comments.
All Answers4
B
Buffer9066
2026-09-17
If you want to load a larger amount, it is recommended to directly switch to a miniprep or midiprep column labeled for high loading capacity, such as a 30-50 μg capacity or a dual-column membrane product. In terms of operation, the bacterial culture can also be enriched by centrifuging it in two batches into the same tube, but P1 resuspension must be thorough; otherwise, residual cell wall material will reduce lysis efficiency. Another common pitfall is antibiotics and culture medium: ampicillin degrades easily, and overnight culture will produce a large number of plasmid-free satellite bacteria, so the OD appears high but the plasmid proportion is low; for pUC19, it is best to use freshly transformed single colonies, shake for 12-14 h, and harvest bacteria at an OD600 of about 1.5, which is more suitable than 2.0. First fix the harvest time and bacterial culture volume before comparing brands; otherwise, the data cannot be attributed.
K
Kit7528
2026-09-21
Longer lysis time is not always better. Alkaline lysis for more than 5 min will cause irreversible breakage of genomic DNA, which instead contaminates the plasmid and also prevents large fragments from being precipitated cleanly. It is recommended to strictly control the process: after adding P2, invert until clear, add N3/P3 within 3 min, place on ice for 5 min after adding the neutralization solution, centrifuge at high speed for 10 min, and take only the clear supernatant. Before elution, preheat the elution buffer to 70°C, add it to the center of the membrane, let it stand for 2 min, and then centrifuge; this can significantly improve recovery. If the Nanodrop reading is 80 ng/μl, also check A260/280 and A260/230. If the ratios are also low, it may be protein or guanidine salt residue, not a loading capacity issue.
P
ProteinMax4620
2026-08-22
The load capacity of the column can be referred to in the instruction manual. Common small lifting columns have a load capacity of 20-35 μ g, while some brands have a load capacity of 50 μ g. Under normal conditions, pUC19 can reach 5-15 μ g per ml of bacterial solution, and theoretically, 3 ml should be able to extract 15-40 μ g. Your actual 4 μ g indicates that the loading has not reached its limit, but rather that the lysis or binding has not been done properly. In terms of brand differentiation, Qiagen's spin miniprep has a stable but expensive loading capacity; Domestic Tian Gen, Nuo Wei Zan, and Kang Wei Xiao extraction columns can often achieve high copy yields of 15-25 μ g, pay attention to whether the lysate is clear. You can compare two brands using the same batch of bacterial solution at the same time, don't just change the washing volume.
N
NinaLab4961
2026-09-10
PUC19 high copy, when OD600 to 2.0, the 3 ml bacterial volume usually exceeds the lysis limit of many small extraction columns. The nominal yield is often achieved using young bacterial solution with OD600 1.0-1.5. In your case, if you first reduce it to 1.5 ml of bacterial solution and keep the other conditions unchanged, the yield often increases instead. It is also possible to split 3 ml of bacterial solution and pass it through the same column twice, but it is more secure to split it into two columns. Your 80 ng/μ l × 50 μ l only has 4 μ g, which is significantly lower. First, rule out incomplete resuspension: there should be no visible bacterial mass after adding P1, and then lyse.