Plasma exosome extraction: can it be done with a 200 µL sample? Looking for a low-sample-volume protocol.

Medical Devices
Asked by:蒋宇洋 2026-09-08 Views 144 5 answers
Back to List ✏️ Ask a Question
💡 How to Answer This Question
  1. 1
    Read the Context

    Read the full description, category and tags to understand the real scenario.

  2. 2
    Give an Actionable Answer

    Give concrete steps, cautions and reasoning — not just a conclusion.

  3. 3
    Cite Sources

    Reference standards, papers or product manuals to make the answer more credible.

  4. 4
    Wait for Acceptance

    You will be notified if accepted. Continue the discussion in comments.

Tags:

All Answers5
质
质控老张 2026-09-20
I have encountered the issue of large elution volumes with imported column-based methods. Domestic membrane affinity columns are actually more flexible in this regard, and many can achieve elution in 80 ul. Contact the manufacturer to request extraction data for small-sample plasma, especially looking at the alignment rate after miRNA sequencing library preparation and exogenous spike-in recovery. I suggest using your existing samples to run 3 replicates: imported column-based method, domestic column-based method, and if necessary, domestic magnetic bead-based method. Within budget, you can discuss trial kits, with cold-chain delivery to Shanghai in 1-2 days. Be sure to ask whether the kit includes DNase treatment, otherwise gDNA will interfere with miRNA quantification.
V
ViviScience3728 2026-09-15
For miRNA sequencing from 200-300 µL plasma, I would not recommend direct precipitation, as background and yield are unstable. Prioritize membrane-affinity spin columns or magnetic bead methods with a small elution volume, requiring the elution volume to be controlled at 50-100 µL to avoid subsequent concentration. Before purchasing, ask the manufacturer whether they can directly extract exosomal RNA, or extract exosomes followed by lysis and then use a microRNA column, as a one-step method saves sample. In Shanghai, SF cold chain usually takes 1-2 days, so have the supplier ship next-day delivery. With a budget of 50-100 RMB per sample, domestic options are available.
董
董娜鹏3053 2026-09-09
Your volume is very limited, so the preprocessing needs to be minimized. First, centrifuge the plasma at 4°C and 3000g for 10 minutes to remove platelets and cell debris; do not subject it to repeated freeze-thaw cycles. After extraction, use a Bioanalyzer or capillary electrophoresis to assess small RNA; do not focus only on the RIN, because plasma exosomal RNA sometimes has a low RIN but a usable small RNA peak. Add a known miRNA spike-in before extraction to monitor yield and inhibitors. If the elution volume is still large, do not exceed 30°C during vacuum centrifugal concentration to avoid RNA degradation.
杨
杨杰琳5914 2026-09-23
After extracting RNA from 200 µL of plasma, the yield may not be sufficient for library construction. At least 500 µL is recommended, unless a dedicated micro-scale kit is used.
K
KitMax2973 2026-09-16
I used a certain imported serum exosome kit, and it can also extract from 150 ul, but the particle count is low, and it is barely enough for qPCR.